{"product_id":"battery-fire-protection-device-automatic-aerosol-fire-suppression","title":"Battery Fire Protection Device – Automatic Aerosol Fire Suppression","description":"\u003cstyle\u003e\n  \/* LiFePO4 Oz – Fire Suppression Device Product Page Styling *\/\n  .l4o-product{\n    --l4o-bg: #ffffff;\n    --l4o-card: #f7f8fa;\n    --l4o-border: #e5e7eb;\n    --l4o-text: #111315;\n    --l4o-muted: #5f6873;\n    --l4o-green: #4f9d22;\n    --l4o-green-dark: #2f6f12;\n    --l4o-green-soft: rgba(79,157,34,0.12);\n    --l4o-red: #e31b23;\n\n    color: var(--l4o-text);\n    font-size: 16px;\n    line-height: 1.55;\n  }\n\n  .l4o-wrap{\n    max-width: 980px;\n    margin: 0 auto;\n  }\n\n  .l4o-hero{\n    background: linear-gradient(180deg, var(--l4o-green-soft), rgba(255,255,255,0));\n    border: 1px solid var(--l4o-border);\n    border-radius: 16px;\n    padding: 20px 18px 16px;\n    margin-bottom: 16px;\n  }\n\n  .l4o-brandline{\n    display: inline-flex;\n    align-items: center;\n    gap: 8px;\n    color: var(--l4o-green-dark);\n    font-weight: 800;\n    font-size: 14px;\n    margin-bottom: 8px;\n    text-transform: uppercase;\n    letter-spacing: 0.04em;\n  }\n\n  .l4o-title{\n    margin: 0 0 8px;\n    font-size: 30px;\n    line-height: 1.18;\n    letter-spacing: -0.03em;\n  }\n\n  .l4o-title span{\n    color: var(--l4o-green);\n  }\n\n  .l4o-sub{\n    margin: 0;\n    color: var(--l4o-muted);\n    font-size: 15px;\n  }\n\n  .l4o-badges{\n    display: flex;\n    flex-wrap: wrap;\n    gap: 8px;\n    margin-top: 14px;\n  }\n\n  .l4o-badge{\n    display: inline-flex;\n    align-items: center;\n    gap: 8px;\n    padding: 8px 11px;\n    border: 1px solid var(--l4o-border);\n    background: #fff;\n    border-radius: 999px;\n    font-size: 13px;\n    color: var(--l4o-muted);\n  }\n\n  .l4o-badge b{\n    color: var(--l4o-text);\n    font-weight: 800;\n  }\n\n  .l4o-grid{\n    display: grid;\n    grid-template-columns: 1.15fr 0.85fr;\n    gap: 14px;\n    margin: 14px 0 18px;\n  }\n\n  @media (max-width: 860px){\n    .l4o-grid{\n      grid-template-columns: 1fr;\n    }\n  }\n\n  .l4o-card{\n    background: var(--l4o-card);\n    border: 1px solid var(--l4o-border);\n    border-radius: 16px;\n    padding: 16px;\n  }\n\n  .l4o-card h2{\n    margin: 0 0 10px;\n    font-size: 20px;\n    line-height: 1.25;\n  }\n\n  .l4o-card h3{\n    margin: 0 0 8px;\n    font-size: 16px;\n  }\n\n  .l4o-card p{\n    margin: 0 0 10px;\n  }\n\n  .l4o-card p:last-child{\n    margin-bottom: 0;\n  }\n\n  .l4o-muted{\n    color: var(--l4o-muted);\n  }\n\n  .l4o-list{\n    margin: 0;\n    padding-left: 18px;\n  }\n\n  .l4o-list li{\n    margin: 6px 0;\n  }\n\n  .l4o-divider{\n    height: 1px;\n    background: var(--l4o-border);\n    margin: 18px 0;\n  }\n\n  .l4o-feature-strip{\n    display: grid;\n    grid-template-columns: repeat(4, 1fr);\n    gap: 10px;\n    margin: 14px 0 18px;\n  }\n\n  @media (max-width: 760px){\n    .l4o-feature-strip{\n      grid-template-columns: 1fr 1fr;\n    }\n  }\n\n  @media (max-width: 460px){\n    .l4o-feature-strip{\n      grid-template-columns: 1fr;\n    }\n  }\n\n  .l4o-feature{\n    background: #fff;\n    border: 1px solid var(--l4o-border);\n    border-radius: 14px;\n    padding: 13px;\n  }\n\n  .l4o-feature .icon{\n    font-size: 24px;\n    margin-bottom: 6px;\n  }\n\n  .l4o-feature b{\n    display: block;\n    margin-bottom: 2px;\n  }\n\n  .l4o-feature span{\n    color: var(--l4o-muted);\n    font-size: 13px;\n  }\n\n  .l4o-table{\n    width: 100%;\n    border-collapse: separate;\n    border-spacing: 0;\n    overflow: hidden;\n    border: 1px solid var(--l4o-border);\n    border-radius: 14px;\n    background: #fff;\n  }\n\n  .l4o-table td{\n    padding: 11px 12px;\n    border-bottom: 1px solid var(--l4o-border);\n    vertical-align: top;\n  }\n\n  .l4o-table tr:last-child td{\n    border-bottom: none;\n  }\n\n  .l4o-table td:first-child{\n    width: 34%;\n    color: var(--l4o-green-dark);\n    font-weight: 800;\n  }\n\n  .l4o-note{\n    font-size: 13px;\n    color: var(--l4o-muted);\n    background: #fff;\n    border: 1px dashed var(--l4o-border);\n    border-radius: 13px;\n    padding: 12px;\n  }\n\n  .l4o-result{\n    background: linear-gradient(135deg, #111111, #292929);\n    color: #ffffff;\n    border-radius: 16px;\n    padding: 18px;\n  }\n\n  .l4o-result h2{\n    margin: 0 0 8px;\n    color: #ffffff;\n    font-size: 20px;\n  }\n\n  .l4o-result strong{\n    color: #9ed66c;\n  }\n\n  details.l4o-faq{\n    background: #fff;\n    border: 1px solid var(--l4o-border);\n    border-radius: 14px;\n    padding: 12px 14px;\n    margin: 10px 0;\n  }\n\n  details.l4o-faq summary{\n    cursor: pointer;\n    font-weight: 900;\n    list-style: none;\n  }\n\n  details.l4o-faq summary::-webkit-details-marker{\n    display: none;\n  }\n\n  .l4o-faq p{\n    margin: 10px 0 0;\n    color: var(--l4o-muted);\n  }\n\u003c\/style\u003e\n\u003csection class=\"l4o-product l4o-fire-suppression-device\"\u003e\n\u003cdiv class=\"l4o-wrap\"\u003e``` \u003c!-- HERO --\u003e\n\u003cdiv class=\"l4o-hero\"\u003e\n\u003cdiv class=\"l4o-brandline\"\u003eLiFePO4 Oz Battery Safety Technology\u003c\/div\u003e\n\u003ch1 class=\"l4o-title\"\u003eLithium Battery \u003cspan\u003eFire Suppression Device\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003cp class=\"l4o-sub\"\u003eA compact 5g hot-gas aerosol Fire Suppression Device designed for lithium battery boxes, PV inverter enclosures, electrical cabinets and other small, relatively enclosed spaces.\u003c\/p\u003e\n\u003cdiv class=\"l4o-badges\"\u003e\n\u003cspan class=\"l4o-badge\"\u003e🔥 \u003cb\u003eAutomatic thermal activation\u003c\/b\u003e\u003c\/span\u003e \u003cspan class=\"l4o-badge\"\u003e⚡ \u003cb\u003e5g aerosol agent\u003c\/b\u003e\u003c\/span\u003e \u003cspan class=\"l4o-badge\"\u003e📦 \u003cb\u003eUp to 0.05m³ protection\u003c\/b\u003e\u003c\/span\u003e \u003cspan class=\"l4o-badge\"\u003e⏱️ \u003cb\u003e≤5-second release delay\u003c\/b\u003e\u003c\/span\u003e \u003cspan class=\"l4o-badge\"\u003e🛡️ \u003cb\u003e10-year validity period\u003c\/b\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- OVERVIEW --\u003e\n\u003cdiv class=\"l4o-grid\"\u003e\n\u003cdiv class=\"l4o-card\"\u003e\n\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eFire Suppression Device\u003c\/strong\u003e is a compact aerosol unit intended for installation inside small, relatively enclosed battery and electrical compartments.\u003c\/p\u003e\n\u003cp\u003eIt contains \u003cstrong\u003e5g of S-type hot-gas aerosol agent\u003c\/strong\u003e and activates thermally at approximately \u003cstrong\u003e160°C to 180°C\u003c\/strong\u003e. Once activated, the unit releases the aerosol within five seconds to help suppress combustion.\u003c\/p\u003e\n\u003cp\u003eIts compact size makes it suitable for lithium battery boxes, energy storage equipment, PV inverter enclosures, electrical cabinets, communications equipment and similar confined spaces.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"l4o-card\"\u003e\n\u003ch2\u003eImportant Information\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eThis is a single-use Fire Suppression Device.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"l4o-muted\"\u003eOnce the device has activated, it must be replaced. The unit should also be replaced when its stated 10-year validity period expires.\u003c\/p\u003e\n\u003cdiv class=\"l4o-note\"\u003eKeep a minimum of 100mm clear in front of the discharge outlet. Do not block the outlet with wiring, equipment or other obstructions.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- FEATURE STRIP --\u003e\n\u003cdiv class=\"l4o-feature-strip\"\u003e\n\u003cdiv class=\"l4o-feature\"\u003e\n\u003cdiv class=\"icon\"\u003e🌡️\u003c\/div\u003e\n\u003cb\u003eThermal Activation\u003c\/b\u003e \u003cspan\u003eActivates at approximately 160°C to 180°C.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"l4o-feature\"\u003e\n\u003cdiv class=\"icon\"\u003e💨\u003c\/div\u003e\n\u003cb\u003eRapid Aerosol Release\u003c\/b\u003e \u003cspan\u003eRelease lag time of five seconds or less.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"l4o-feature\"\u003e\n\u003cdiv class=\"icon\"\u003e📦\u003c\/div\u003e\n\u003cb\u003eCompact Protection\u003c\/b\u003e \u003cspan\u003eDesigned for enclosed volumes up to 0.05m³.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"l4o-feature\"\u003e\n\u003cdiv class=\"icon\"\u003e🛡️\u003c\/div\u003e\n\u003cb\u003e10-Year Validity\u003c\/b\u003e \u003cspan\u003eLong-term installed protection before scheduled replacement.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- HOW IT WORKS --\u003e\n\u003cdiv class=\"l4o-card\"\u003e\n\u003ch2\u003eHow the Fire Suppression Device Works\u003c\/h2\u003e\n\u003ctable class=\"l4o-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermal activation\u003c\/td\u003e\n\u003ctd\u003eThe thermal lead activates when exposed to temperatures of approximately 160°C to 180°C.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAerosol generation\u003c\/td\u003e\n\u003ctd\u003eOnce activated, the device produces an S-type hot-gas aerosol that fills the protected enclosure.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling effect\u003c\/td\u003e\n\u003ctd\u003eFine aerosol particles absorb part of the heat released by the fire, helping to reduce flame temperature.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas-phase inhibition\u003c\/td\u003e\n\u003ctd\u003eAerosol components react with active combustion particles, reducing the free radicals required to sustain the flame.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSolid-phase inhibition\u003c\/td\u003e\n\u003ctd\u003eSolid particles help absorb and neutralise combustion intermediates, further interrupting the fire reaction.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"l4o-divider\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c!-- APPLICATIONS --\u003e\n\u003cdiv class=\"l4o-card\"\u003e\n\u003ch2\u003eSuitable Applications\u003c\/h2\u003e\n\u003cul class=\"l4o-list\"\u003e\n\u003cli\u003eLithium-ion and LiFePO4 battery boxes\u003c\/li\u003e\n\u003cli\u003eBattery compartments and battery cabinets\u003c\/li\u003e\n\u003cli\u003eEnergy storage equipment\u003c\/li\u003e\n\u003cli\u003ePV and hybrid inverter enclosures\u003c\/li\u003e\n\u003cli\u003eElectrical control cabinets\u003c\/li\u003e\n\u003cli\u003ePower distribution cabinets\u003c\/li\u003e\n\u003cli\u003eCommunication equipment\u003c\/li\u003e\n\u003cli\u003eGenerator and engine compartments\u003c\/li\u003e\n\u003cli\u003eCable compartments, wells and trenches\u003c\/li\u003e\n\u003cli\u003eOther relatively enclosed electrical spaces\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"l4o-divider\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c!-- SPECIFICATIONS --\u003e\n\u003cdiv class=\"l4o-card\"\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable class=\"l4o-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eFire Suppression Device\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eQRR0.005G\/S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExtinguishing Agent\u003c\/td\u003e\n\u003ctd\u003eS-Type Hot-Gas Aerosol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAerosol Agent Quantity\u003c\/td\u003e\n\u003ctd\u003e5g ±1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Activation Method\u003c\/td\u003e\n\u003ctd\u003eThermal activation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional Activation\u003c\/td\u003e\n\u003ctd\u003eElectric activation or combined thermal and electric activation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eActivation Temperature\u003c\/td\u003e\n\u003ctd\u003e160°C to 180°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelease Lag Time\u003c\/td\u003e\n\u003ctd\u003e≤5 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtected Volume\u003c\/td\u003e\n\u003ctd\u003eUp to 0.05m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Operating Temperature\u003c\/td\u003e\n\u003ctd\u003e-50°C to +90°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e80 × 40 × 10mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice Weight\u003c\/td\u003e\n\u003ctd\u003eApprox. 30g ±10g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermal Lead Length\u003c\/td\u003e\n\u003ctd\u003eApprox. 200mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eM3 screw fixing points on both sides\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDischarge Direction\u003c\/td\u003e\n\u003ctd\u003eSingle-end discharge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNozzle Temperature\u003c\/td\u003e\n\u003ctd\u003e≤200°C measured 5mm from the nozzle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eValidity Period\u003c\/td\u003e\n\u003ctd\u003e10 Years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplicable Fire Classes\u003c\/td\u003e\n\u003ctd\u003eClass A, B, C and E fires in relatively enclosed spaces\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"l4o-divider\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c!-- RESULT --\u003e\n\u003cdiv class=\"l4o-result\"\u003e\n\u003ch2\u003eCompact Protection for Confined Electrical Spaces\u003c\/h2\u003e\n\u003cp\u003eThe QRR0.005G\/S provides an \u003cstrong\u003eautomatic, compact and pipe-free fire suppression solution\u003c\/strong\u003e for lithium battery, inverter and electrical applications where space is limited.\u003c\/p\u003e\n\u003cp\u003eIts thermal activation, rapid aerosol release and small form factor make it suitable as an additional protection device inside compatible enclosed equipment.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"l4o-divider\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c!-- SAFETY --\u003e\n\u003cdiv class=\"l4o-card\"\u003e\n\u003ch2\u003eInstallation and Safety Notes\u003c\/h2\u003e\n\u003cul class=\"l4o-list\"\u003e\n\u003cli\u003eKeep at least 100mm clear in front of the discharge outlet.\u003c\/li\u003e\n\u003cli\u003eDo not obstruct the outlet with wiring, equipment or debris.\u003c\/li\u003e\n\u003cli\u003eUse the M3 mounting points to secure the device.\u003c\/li\u003e\n\u003cli\u003eDo not dismantle the device.\u003c\/li\u003e\n\u003cli\u003eReplace the unit after activation.\u003c\/li\u003e\n\u003cli\u003eReplace the unit when the 10-year validity period expires.\u003c\/li\u003e\n\u003cli\u003eAfter discharge, allow the housing to cool before touching it.\u003c\/li\u003e\n\u003cli\u003eInstallation should be completed by a suitably qualified person.\u003c\/li\u003e\n\u003cli\u003eThe device is intended for relatively enclosed spaces.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"l4o-divider\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c!-- FAQ --\u003e\n\u003cdiv class=\"l4o-card\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cdetails open=\"\" class=\"l4o-faq\"\u003e\n\u003csummary\u003eIs the Fire Suppression Device reusable?\u003c\/summary\u003e\n\u003cp\u003eNo. The device is single-use and must be replaced after activation.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"l4o-faq\"\u003e\n\u003csummary\u003eDoes the Fire Suppression Device need external power?\u003c\/summary\u003e\n\u003cp\u003eThe standard version is thermally activated and does not require an external power supply. Electric activation may be available as an optional configuration.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"l4o-faq\"\u003e\n\u003csummary\u003eWhat volume can it protect?\u003c\/summary\u003e\n\u003cp\u003eThe device is intended for relatively enclosed spaces with a volume of up to 0.05m³.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"l4o-faq\"\u003e\n\u003csummary\u003eWhat temperature activates the device?\u003c\/summary\u003e\n\u003cp\u003eThe thermal activation temperature is approximately 160°C to 180°C.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"l4o-faq\"\u003e\n\u003csummary\u003eHow long is the device valid?\u003c\/summary\u003e\n\u003cp\u003eThe stated validity period is 10 years. It must also be replaced immediately after activation.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"l4o-faq\"\u003e\n\u003csummary\u003eCan it be installed inside a lithium battery box?\u003c\/summary\u003e\n\u003cp\u003eYes. It is designed for small, relatively enclosed spaces such as lithium battery boxes, battery compartments and electrical enclosures, subject to correct system design and installation.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n```\u003c\/div\u003e\n\u003c\/section\u003e","brand":"LiFePO4 OZ","offers":[{"title":"Default Title","offer_id":62839138091167,"sku":"DC-QRJ001","price":59.95,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0575\/4562\/1663\/files\/FireSuspressionModule-1.png?v=1785226048","url":"https:\/\/lifepo4oz.com\/products\/battery-fire-protection-device-automatic-aerosol-fire-suppression","provider":"LiFePO4 OZ","version":"1.0","type":"link"}